PLANT ROOM BUND - NORTHAMPTON

34 Fd5 Dfa 52 C0 430 B A17 B 98 C27120 Adba 1 105 C

This 1st floor plant room bund was proved to be leaking after our client had carried out a water evaporation test.

The internal surfaces of the bund had been coated with bituminous paint that was not chemically resistant to the hydraulic oils contained within the bund.

74 Fc9540 0094 4798 B477 E0 Acf00 Bb0 F5 1 105 C

The existing coating was removed from the concrete surfaces of the bund using a HILTI concrete grinder fitted with a diamond disc and connected to a dust vac.

0 C387252 B5 F1 4473 Be28 B560 B07722 Dc 1 105 C

The cleaned and keyed surfaces were primed with a solvent free epoxy floor sealer.

Ec99 Cda3 447 F 4 Ec4 9786 E253300 D848 A 1 105 C

The final application of 2 coats of an oil resistant glass flake epoxy system ensured watertightness for at least the next 10 years.